Vue de la page 0
P:\INSTALLATION INST\SWITCH KITS\INST-LRY1R.vsd REV - 07-12 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
INSTALLATION INSTRUCTIONS
LRY1R REX STATUS KIT
7000 SERIES YALE DEVICES
Remove Device End Cap and cover.
Position the switch bracket where
shown and attach to the device with
the two supplied #8-32 screws.
Re-attach Cover and End Cap.
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
Applications
Remote Latch Status Monitoring:
Retracting the latch by depressing the push
pad provides an output signal for local or
remote visual and audible annunciation
indicating forced entry or unauthorized
egress.
Access Control REX: When connected to
the Request-To-Exit input of a keypad,
card or biometric Access Controller,
depressing the pushpad and retracting the
latch actuates the Latch Status contact,
shunting the control access control alarm
to permit authorized egress and/or
releases the magnetic door lock for
uninhibited egress.
Magnetic Lock Release: Where Access
Controller with REX input is unavailable,
the N/C contact of the switch is wired in
series between the power supply and fail
safe magnetic lock. Depressing the exit
device pushpad retracts the latch, causing
the contact to open, thereby releasing the
magnetic lock for uninhibited egress.
Mantrap Logic: Provides N/O and N/C
contacts required for 2 or more
communicating doors for Interlock and
Mantrap applications.
WHT – COM GRN – N/O RED – N/C