Sdc LR100DXK DETEX ELECTRIC LATCH RETRACTION DEVICE KI Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pour la maison Sdc LR100DXK DETEX ELECTRIC LATCH RETRACTION DEVICE KI. SDC LR100DXK DETEX ELECTRIC LATCH RETRACTION DEVICE KIT 10, 20, 40, 50, 60 & 80 SERIES User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
P:\INSTALLATION INST\SWITCH KITS\INST-LR100DXK.vsd REV C 10-13 Page 1
INSTALLATION INSTRUCTIONS LR100DXK
DETEX ELECTRIC LATCH RETRACTION DEVICE KIT
MODELS: 10, 20, 40, 50, 60 & 80 SERIES
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
STEP 3
Re-install Pushpad assy. Slide the LR100DXK into the device and
attach the linkage to the clevis. Back the assembly out until the
linkage JUST makes contact with the clevis. Secure in place with the
two #8-32 socket set screws supplied. Wire the unit to power and
replace the Cover, End Cap Mounting Plate and End Cap.
ELECTRICAL DATA
24VDC @ 700/200mA
RED (+) BLK (-)
PATENT PENDING
STEP 2
Install the linkage from the bottom of the
Pushpad assy. Place the spacer over
the existing tapped hole inside the base
where shown. Carefully place the screw
and washer over the linkage and spacer
and tighten into the Pushpad base.
NOTE Retro-Fitting Vertical Rod Devices:
Before retro-fitting an electric latch assembly into a vertical device, the following must be done to
ensure proper alignment. Disconnect the vertical rods from the device head. Install the electric
latch assembly as shown above. Once the ELR is properly installed energize it so that the push pad
is dogged down, by doing so it will allow for proper alignment for the vertical rods. Finally reconnect
the vertical rods to the device and make the proper adjusments.
#10-24
WASHER
LINKAGE
SPACER
#8-32
SOCKET
SCREWS
Back assembly out until
the linkage JUST makes
contact with the clevis
STEP 1
Carefully remove the Cover, End Cap and
End Cap Mounting Plate. If present, remove
existing Dogging. Slide Pushpad assy. out
of the Extrusion and Inner Sleeve.
STEP 2
Pushpad assy.
Exterior Extrusion
Inner Sleeve
Cover*
End Cap Mtg. Plt.
End Cap
*Value Series REQUIRES a
modified cover; either order
Detex Part #100518-11 or modify
existing cover per page 2
Vue de la page 0
1 2

Résumé du contenu

Page 1 - *Value Series REQUIRES a

P:\INSTALLATION INST\SWITCH KITS\INST-LR100DXK.vsd REV C 10-13 Page 1 INSTALLATION INSTRUCTIONS LR100DXKDETEX ELECTRIC LATCH RETRACTION DE

Page 2 - Remove metal inserts

P:\INSTALLATION INST\SWITCH KITS\INST-LR100DXK.vsd REV C 10-13 Page 2Use small wire cutters to snip off all the ribs.Cut out the front wall

Commentaires sur ces manuels